Abstract | Fast-continuous-rotation is an effective measure to improve the scanning speed and decrease the radiation dose for cone-beam CT. However, because of acceleration and deceleration of the motor, as well as the response lag of the scanning control terminals to the host PC, uneven-distributed and redundant projections are inevitably created, which seriously decrease the quality of the reconstruction images. In this paper, we first analyzed the aspects of the theoretical sequence chart of the fastcontinuous- rotation mode. Then, an optimized sequence chart was proposed by extending the rotation angle span to ensure the effective 2 pi-span projections were situated in the stable rotation stage. In order to match the rotation angle with the projection image accurately, structure similarity (SSIM) index was used as a control parameter for extraction of the effective projection sequence which was exactly the complete projection data for image reconstruction. The experimental results showed that SSIM based method had a high accuracy of projection view locating and was easy to realize. |
Keyword | Cone-beam Ct Fast-continuous-rotation Scanning Data Redundancy Structural Similarity |
Subtype | Article |
WOS Headings | Science & Technology ; Technology ; Physical Sciences |
Indexed By | SCI |
Language | 英语 |
WOS Keyword | MICRO-CT ; IMAGE-RECONSTRUCTION ; COMPUTED-TOMOGRAPHY ; SYSTEM ; ALGORITHM ; MINIMIZATION ; ARTIFACT |
WOS Research Area | Instruments & Instrumentation ; Optics ; Physics |
WOS Subject | Instruments & Instrumentation ; Optics ; Physics, Applied |
WOS ID | WOS:000326747000003 |
Citation statistics | |
Document Type | 期刊论文 |
Identifier | http://ir.ipe.ac.cn/handle/122111/13508 |
Collection | 研究所(批量导入) |
Affiliation | 1.Beijing Univ Aeronaut & Astronaut, Sch Mech Engn & Automat, Beijing 100191, Peoples R China 2.China Informat Secur Certificat Ctr, Beijing, Peoples R China 3.Natl Inst Metrol, Beijing, Peoples R China 4.Chinese Acad Sci, Inst Proc Engn, State Key Lab Multiphase Complex Syst, Beijing 100190, Peoples R China 5.Sungkyunkwan Univ, Sch Mech Engn, Seoul, South Korea |
Recommended Citation GB/T 7714 | Yang, Min,Duan, Shengling,Duan, Jinghui,et al. Extra projection data identification method for fast-continuous-rotation industrial cone-beam CT[J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY,2013,21(4):467-479. |
APA | Yang, Min.,Duan, Shengling.,Duan, Jinghui.,Wang, Xiaolong.,Li, Xingdong.,...&Zhang, Jianhai.(2013).Extra projection data identification method for fast-continuous-rotation industrial cone-beam CT.JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY,21(4),467-479. |
MLA | Yang, Min,et al."Extra projection data identification method for fast-continuous-rotation industrial cone-beam CT".JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 21.4(2013):467-479. |
Files in This Item: | ||||||
File Name/Size | DocType | Version | Access | License | ||
Extra projection dat(1650KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | Application Full Text |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment