Molecular Imprinting-Flow Injection Chemiluminescence Method for Determination of Doxycycline Hydrochloride
Zhou Yan-mei1; Zhang Cheng-li1; Lei Jian-du2; Ma Tong-sen1; Ma Guang-hui2; Su Zhi-guo2; Chao Yang1; Zhou, YM
2009-07-01
Source PublicationSPECTROSCOPY AND SPECTRAL ANALYSIS
ISSN1000-0593
Volume29Issue:7Pages:1745-1749
AbstractDoxycycline hydrochloride can enhance the chemiluminescence of potassium ferricyanide and luminol in alkaline medium. So a molecular imprinting-flow injection chemiluminescence method for the determination of doxycycline hydrochloride was established by using doxycycline hydrochloride-imprinted polymers as recognition material and potassium ferricyanide and luminol as detection system. Doxycycline hydrochloride-imprinted polymer was synthesized using methacrylic acid as functional monomer and ethylene glycol dimethacrylate as cross-linker. The linear range is 9.0 x 10(-7)-6.0 x 10(-5) g.mL(-1) and the detection limit is 3.2 x 10(-7) g.mL(-1). The relative standard deviation for 6.0 x 10(-6) g.mL(-1) of doxycycline hydrochloride was 3.5% (n = 9). This method has been successfully applied to the determination of doxycycline hydrochloride in tablets and in urine samples.
KeywordMolecularly Imprinted Polymer Flow Injection Chemiluminescence Doxycycline Hydrochloride
SubtypeArticle
WOS HeadingsScience & Technology ; Technology
Indexed BySCI
Language英语
WOS KeywordRECOGNITION ; POLYMERS
WOS Research AreaSpectroscopy
WOS SubjectSpectroscopy
WOS IDWOS:000267632100005
Citation statistics
Cited Times:3[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Version出版稿
Identifierhttp://ir.ipe.ac.cn/handle/122111/6645
Collection生化工程国家重点实验室
Corresponding AuthorZhou, YM
Affiliation1.Henan Univ, Coll Chem & Chem Engn, Kaifeng 475004, Peoples R China
2.Chinese Acad Sci, Inst Proc Engn, Natl Key Lab Biochem Engn, Beijing 100080, Peoples R China
Recommended Citation
GB/T 7714
Zhou Yan-mei,Zhang Cheng-li,Lei Jian-du,et al. Molecular Imprinting-Flow Injection Chemiluminescence Method for Determination of Doxycycline Hydrochloride[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2009,29(7):1745-1749.
APA Zhou Yan-mei.,Zhang Cheng-li.,Lei Jian-du.,Ma Tong-sen.,Ma Guang-hui.,...&Zhou, YM.(2009).Molecular Imprinting-Flow Injection Chemiluminescence Method for Determination of Doxycycline Hydrochloride.SPECTROSCOPY AND SPECTRAL ANALYSIS,29(7),1745-1749.
MLA Zhou Yan-mei,et al."Molecular Imprinting-Flow Injection Chemiluminescence Method for Determination of Doxycycline Hydrochloride".SPECTROSCOPY AND SPECTRAL ANALYSIS 29.7(2009):1745-1749.
Files in This Item:
File Name/Size DocType Version Access License
20131217-2-复件 BJ0129(220KB) 限制开放CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Zhou Yan-mei]'s Articles
[Zhang Cheng-li]'s Articles
[Lei Jian-du]'s Articles
Baidu academic
Similar articles in Baidu academic
[Zhou Yan-mei]'s Articles
[Zhang Cheng-li]'s Articles
[Lei Jian-du]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Zhou Yan-mei]'s Articles
[Zhang Cheng-li]'s Articles
[Lei Jian-du]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.